Leave Your Message
Microbial Air Sampler ZR-2052

Biosafety cabinet & clean room

Microbial Air Sampler ZR-2052

Microbial air samplers are the industry standard for use in cleanrooms and critical environments.

  • Sampling flow 100L/min
  • Impact velocity 10.8 m/s
  • Preset points ≥200000 points
  • Range of Sampling volume 1-9999L
  • Specification of petri dish Ф90mm, Ф100mm
  • Power AC100~240V 50/60Hz, DC15V 3A
  • Working temperature (-20~50)℃
  • Size of host (L125×W128×H217)mm
  • Weight of host about 2kg
  • Host power consumption <15W

The model 2052 has high collection efficiency for precise and reproducible measurements. Microbiological air sampler is used to detect microorganisms content in the atmosphere by aspiration method at different stages of the operational process in order to analyze their presence and concentration.

配置1.jpg


选配2.jpg

ZR-G01 Compressed gas sampling head

Product Detail

G01 should operate with ZR-2052 host, is used to detect microbial content in compressed gas.

> Equip a pressure valve to reduce compressed pipeline pressure.

> Material is anodized aluminum, easy for disinfection.

> Flowmeter is made of high-pressure-resistant material, which has high-pressure resistance and good pressure reduction.

Parameter

 Description Error                   

Parameter

Flow range

(0~6000)L/min, adjustable        

±4%

Pressure range

(0~10)Mpa

Operating temperature

(0~65)℃

Weight

<1kg




ISO 14698-1

BS EN 17141

> Aspiration rate stable at 100 l/min, volume range 1-9999L.

> 304 stainless steel material, with a total of 400 holes and aperture φ 0.6mm, impact velocity 10.8m/s

> Can set loop sampling, delay sampling, interval sampling.

> Build-in lithium battery, keep sampling up to 6 hours.

> Audit trail function & user management, ensure data integrity.

> Sampling from environmental air and compressed air.

> Excel reports such as User Audit Trails, GMP metadata reports, audit logs, stored data, and program settings are provided.

> Double sampling mode for time and volume.

> Preset points in a cleanroom.

The main parameter

Parameter range

Resolution

Error

Sampling flow

100L/min

1L/min

±2.5%

Impact velocity

10.8 m/s

Preset points

≥200000 points

Loop sampling

0~23h59min59s, 8 preset delay times

Delay sampling

0-999 times, preset 8 sampling cycles

Interval sampling

0-23h59min59s, with preset 8 intervals

Range of Sampling volume

1-9999L

Specification of petri dish

Ф90mm, Ф100mm

Data Storage

1000000

Instrument noise

<60dB(A)

Battery working time

>6h

Power

AC100~240V 50/60Hz, DC15V 3A

Working temperature

(-20~50)℃

Size of host

(L125×W128×H217)mm

Weight of host

about 2kg

Host power consumption

<15W