THC Analyzer FID 3000
What is Leak Detection and Repair (LDAR)?
Leak Detection and Repair (LDAR) is the process by which oil and gas, chemical, and/or petrochemical equipment is monitored for the location and volume of unintended leaks. LDAR requires manufacturing organizations to account for volatile organic compounds (VOCs) they emit into the atmosphere. These leaks must be reported on an annual or semiannual basis as required by multiple governments around the world to stem the harmful environmental impact of VOC emissions.
Standards
Governments globally are implementing LDAR regulations to combat the health and environmental impacts of liquid and gas leaks. The primary targets for these regulations are VOCs and HAPs (hazardous air pollutants) emitted from petroleum refineries and chemical manufacturing facilities.
US method 21
SOR/2020-231
EN 15446
Features
As a portable environmental analyzer, THC Analyzer has more than 1000 clients and many advantages:
• WIDE RANGE & FAST RESPONSE
> FID sensor wide range: 1-50000ppm
> Fast response time<3.5s
> Dual FID/PID technology, O2 senor are also acceptable.
• STABILITY OF FID FLAMES
> Bypass design. When O2 is below 16%, don’t worry about FID flames will flame down.
• PORTABILITY & BATTERY
> Built in explosion-proof battery with a long service life.
> Portable, smaller, exquisite appearance. FID 3000 is more friendly and easier for the users.
• EXTERNAL Bluetooth CONTROL
> FID 3000 includes powerful datalogging software that can be used to create electronic records of inspections.
> Users can check data in Mobile phone from LDAR Software or print real-time data by bluetooth printer.
• CONTROL OF HYDROGEN
> Built in a solid hydrogen cylinder.
> Explosion protected and easy to replaceable
• EXPLOSION-PROOF QUALIFIED
Deliver Goods
Gas leakage from refineries and chemical factory
Petroleum and petrochemical industry
A portable FID analyzer that measures VOCs in ambient air. This latest LDARtools to optimize your measurements in fugitive emissions in ATEX environments.
Parameters |
Range |
Accuracy |
|
Linear |
FID |
1-50000ppm of methane |
±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm. |
O2 |
0~30% |
±5% |
|
Repeatability |
±2% at 500 ppm of methane |
||
Detection limit |
0.5 ppm of methane |
||
Response time |
Less than 3.5 seconds for 90% of final value, using 10000 ppm of methane |
||
Flowrate |
1.2L/min±10% |
||
Battery |
Operating time more than 10 hours at 0 °C. Fully charged in less than 10 hours. |
||
Hydrogen supply operating time |
10 hours of continuous operation, starting from a cylinder charged up to 15.3 MPa (2200 psi) |
||
Data Storage |
1 per second to 999 minutes Data storage interval: every 15s |
||
Host Size |
H280 x L220 x T90 mm |
||
Host Weight |
FID only: about 3kg |
||
Working Condition |
(-10~+45)℃, (15 ~ 95)%RH |