Umhloli we-ZR-1000C Mask Bacterial Filtration Efficiency (BFE).

Incazelo emfushane:

Ukucaciswa okubalulekile kwe-Model ZR-1000 mask bacteria filtration effective tester (BFE) akuhlangabezani kuphela nezimfuneko ze-B.1.1 ku-YY0469-2011 , kodwa futhi ihlangabezana nezidingo zamazinga e-ASTMF2100, ASTMF2101 kanye ne-European EN14683.


  • Isampula Lesilinganiso sokugeleza sika-A:28.3L/min
  • Izinga Lokugeleza Lesampula lika-B:28.3L/min
  • Izinga lokugeleza kwe-Nebulization:(0.1~10)L/min
  • Ukugeleza kwepompo ye-Peristaltic:(0.001–3.0) mL/min
  • Isamba senani lesampula yokulawula ikhwalithi enhle:(2200±500) CFU/mL
  • Usayizi womsingathi:(ubude 1050× ububanzi 635× ukuphakama 1310) mm
  • Isisindo somshini wonke:Cishe i-180 kg
  • Imininingwane Yomkhiqizo

    Ukucaciswa

    Ukucaciswa okubalulekile kwe-Model ZR-1000 mask bacteria filtration effective tester (BFE) akuhlangabezani kuphela nezimfuneko ze-B.1.1 ku-YY0469-2011 , kodwa futhi ihlangabezana nezidingo zamazinga e-ASTMF2100, ASTMF2101 kanye ne-European EN14683. Ngaphezu kwalokho, senze intuthuko emisha ngokusekelwe kulokhu, ngendlela yesampula yokuhluka kwegesi ekabili ngesikhathi esifanayo, sithuthukisa ukunemba kwesampula. Isebenza ekuhlolweni kokusebenza kwe-mask yokuhlunga amagciwane ngokusebenza kahle komnyango wokuqinisekisa i-metrological, izikhungo zocwaningo lwesayensi, abakhiqizi bemaski neminye iminyango efanele.

    Izici

    > Uhlelo lokuhlola ingcindezi engemihle luqinisekisa ukuphepha kwabaqhubi;

    > Ikhabhinethi yengcindezi engemihle ifakwe iphampu ye-peristaltic, i-A kanye ne-B yezindlela ezimbili zesiteji sesithupha sika-Anderson sampler;

    > Ukugeleza kwepompo ye-peristaltic kungasethwa;

    > Izinga lokugeleza kwejeneretha ye-aerosol ekhethekile ye-microbial ingasethwa.

    > Ukusebenza kahle kwe-nebulization, usayizi we-aerosol uvumelana namazinga omhlaba;

    > Ilawulwa yi-microcomputer yezimboni enesivinini esikhulu;

    > isikrini sokuthinta esinombala esingu-10.4-intshi esiphezulu;

    > Imbobo ye-USB, esekela ukudluliswa kwedatha kwi-USB flash disk;

    > Sekela ukuphrinta kwe-Bluetooth;

    > Izibani ezikhanyayo eziphakeme ezakhelwe ngaphakathi;

    > Iswishi eyakhelwe ngaphakathi yokuvikela ukuvuza ukuze kuvikelwe ukuphepha kwabaqhubi;

    > Ungqimba lwangaphakathi lwekhabhinethi lwenziwe ngensimbi engagqwali, futhi ungqimba lwangaphandle luyishidi eligoqiwe elibandayo elifuthwe ngepulasitiki;

    > Ukugcina ukushisa kanye ne-flame retardant isethwe phakathi kwezingqimba zangaphakathi nezingaphandle;

    > Umnyango wengilazi ovulelekayo wangaphambili ulungele ukuthi opharetha ohlolayo awubuke futhi awusebenzise;

    > Isibambi esikhiphekayo, kanye ne-caster ingasetshenziselwa ukusekela nokunyakaza.

    > Isikrini sokubonisa esiphendukayo esihoxiswayo, esilungele ukusebenza;

    > Ikhabhinethi yengcindezi engemihle inebhodi likakhiye wokusebenza elakhelwe ngaphakathi, elimelana nokugqwala futhi limelana ne-UV, lenze kube lula ukusebenza.

    Amazinga

    EN14683-2019

    I-ASTM F2100, STM F2101

    YY 0469-2011

    YY/T 0969-2013

    I-GB/T 38880-2020

    T/CNTAC 55—2020 T/CNITA 09104——2020

    T/CTCA 7—2019 

    Diliva Izimpahla

    ukuletha izimpahla Italy
  • Okwedlule:
  • Olandelayo:

  • Amapharamitha amakhulu

    Ibanga lepharamitha

    Isixazululo

    I-MPE (Iphutha Eliphezulu Elivumelekile)

    Isampula Lokugeleza Kwesilinganiso sika-A

    28.3L/min

    0.1L/min

    ±2.0%

    Isampula Lokugeleza Kwesilinganiso sika-B

    28.3L/min

    0.1L/min

    ±2.0%

    Izinga lokugeleza kwe-Nebulization

    (0.1~10)L/min

    0.1L/min

    ±5.0%

    Ukugeleza kwepompo ye-Peristaltic

    (0.001–3.0) mL/min

    0.01mL/min

    ±2.0%

    Ingcindezi yangaphambili ye-A-path flowmeter

    (-20⽞0)kPa

    0.1kPa

    ±2.5%

    Ingcindezi yangaphambili ye-B-path flowmeter

    (-20⽞0)kPa

    0.01kPa

    ±2.5%

    Ingcindezi yangaphambili ye-nebulizer

    (0–50)kPa

    0.01kPa

    ±2.5%

    Ingcindezi engemihle egumbini le-aerosol

    (-90-120) Kuhle

    0.1Pa

    ±1.0%

    Izinga lokushisa lokusebenza

    (0~50)℃

    Ingcindezi engemihle yeKhabhinethi

    (-50~-200) Kuhle

    Amandla okugcina idatha

    >500000 amaqembu

    Izici zesihlungi se-HEPA

    ≥ 99.995%@0.3μm, ≥ 99.995%@0.12μm

    Isilinganiso esikhulu se-aerosol

    Isilinganiso sobubanzi bezinhlayiyana ngu-(3.0 ± 0.3)μm, ukuchezuka okujwayelekile kwejometri ≤ 1.5

    Usayizi wezinhlayiyana othwetshuliwe wesampula ye-Anderson enezinyathelo ezingu-6 enezinyathelo ezimbili

    1st stage > 7 μm, 2nd stage (4.7-7) μm, 3rd stage (3.3-4.7) μm, 4th stage(2.1-3.3) μm, 5th stage (1.1-2.1) μm, 6th stage (0.6-1.1) μm

    Ubukhulu bekamelo le-aerosol

    (ubude 600× ububanzi 85× ukujiya 3) mm

    Isamba senani lesampula yokulawula ikhwalithi enhle

    (2200±500) CFU/mL

    Izinga lokugeleza komoya wekhabhinethi yengcindezi engalungile

    ≥5m3/min

    Ubukhulu bomnyango wekhabethe lengcindezi engalungile

    (ubude 1100× ububanzi 780) mm

    Usayizi womsingathi

    (ubude 1050× ububanzi 635× ukuphakama 1310) mm

    Usayizi wabakaki

    (ubude 1050× ububanzi 635× ukuphakama 650) mm

    Ukunikezwa kwamandla kagesi

    I-AC220V±10%,50Hz

    Umsindo wezinsimbi

    <65dB(A)

    Isisindo somshini wonke

    Cishe i-180 kg

    Ukusetshenziswa kwamandla sekukonke

    <500W