ZR-3260 Intelligent Stack dust( gas) Tester

Short Description:

ZR 3260 intelligent stack dust(gas) tester is a portable instrument. It adopts isokinetic sample and membrane filter (cartridge) weighing method to measure dust concentration while using electrochemistry or optical principle sensor  to analyze O2,SO2, NOx, CO and other poisonous and harmful gas concentration.And also the velocity of flue gas, flue gas temperature, flue gas humidity,  flue pressure and exhaust air rate etc.It’s suitable for stationary pollutant source dust and flue gas concentrations ,total amount of emission dust removal and desulphurization efficiency monitoring.


Product Detail

Product Tags

Application
1)All kinds of boilers, industrial furnaces stack dust concentration, converted concentration and the determination of total emissions
2)sampling cooking fume with specific sampling probe
3)measurement for dust removing plant efficiency
4)flue gas parameter(dynamic pressure,static pressure,temperature,flowrate ,standard dry flowrate)
5)O2 content of flue gas and air excess coefficient measurement
6)dry/wet ball temperature measurement
7)assessment and calibration for CEMS accuracy
8)All kinds of boilers, industrial furnaces SO₂、NOx emission concentration measurement and desulphurization efficiency monitoring(optional)
9)Other application
Features
1)Tested by the quality inspection center of the Chinese government.
2)Isokinetic tracking sampling,Rapid response.
3)Accurate electronic flowmeter control, real-time monitoring of temperature and pressure, and automatic flow regulation.
4)Built in automatic drainage pump, which can be used under high humidity conditions.
5)5.0 -inch color screen ,touch operation , wide working temperature , clear Visual in sunshine.
6)Real time storage of sampling data, and support export storage of SD card, USB flash disk, etc
7)AC / DC voltage supply(220V),Self contained battery(25.9V 6AH)≥2H
8)Leakage self detection function,suck-back proof function,keep low gas exhaust when sample pause or end in order to protect dust suck back to the flue.
9)Power-off memory function,continue to sample procedure when recovery.
Standard
对勾小GB/T 16157-1996 Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
对勾小HJ 57-2017 Determination of sulfur dioxide in waste gas from fixed pollution sources constant potential electrolysis
对勾小HJ 693-2014 Determination of nitrogen oxides in waste gas from fixed pollution sources constant potential electrolysis
对勾小HJ 973-2018 Determination of carbon monoxide in exhaust gas from fixed pollution sources constant potential electrolysis
Principle
1)Particular isokinetic sampling
Place the sampling probe into the smoke flue , and puts nozzle on the sample point facing airflow direction ,sample a certain amount of dust according to the isokinetic sampling requirements.Gas cartridge according to capture of smoke sampling volume.And then  calculate  emissions  of particulate matterconcentrations and  emission total quantity.
According to static pressure,dynamic pressure,temperature and humidity from all different sensors,MPU automatically calculates flue gas flowrate,isokinetic tracing flowrate and makes a comparison between the computed flowrate and the real flowrate .Then computes response control signals to control the exhaust gas capacity to make the actual flow equals to the calculated sampling flow.
2)Humidity
MPU controls sensors to measure wet ball,dry ball, wet ball surface pressure and exhausted static pressure.Combined with temperature of wet ball surface temperature to trace the related saturated vapor pressure–Pbv,calculates flue gas humidity in accordance with formula.
3)O2 measurement
Put the sampling probe to extract flue gas with O2 and measure instant O2 content.According to O2 content, computes air excess coefficient α.
4)Poisonous gas instant concentration emission load measurement principle.
Put the sampling probe into the stack to extract flue gas including SO2,NOx.After dedusting and dehydration treatment,through SO2,NOx electrochemistry sensor,the following reaction will happen;
SO₂+2H₂O —> SO⁴- + 4H++2e-
NO +2H₂O —> NO³- + 4H++3e-
Under certain conditions, the size of the sensor output current is proportional to the concentration of SO2, NO.According to the measurement of the sensor output current ,can be calculated instantaneous concentration of SO2, NOx.At the same time, according to the test flue gas emissions parameters, instruments t can calculates SO2 and NOx emissions.
Working conditions
对勾小Power supply:AC220V±10%,50Hz or DC24V 12A
对勾小Ambient temperature:(-20~ 45 )℃
对勾小Ambient humidity:0% ~95%
对勾小Application environment: Non-explosionproof
对勾小When used in wild,some measurement should be adopt to prevent the damage caused by rain,snow,dust and sunshine.
对勾小Good power grounding
Technical Parameter
6.1 Stack dust technical index

Parameter

Range

Resolution

Error

Sampling flowrate

(0~80)L/min

0.1L/min

±2.5%

Flowrate control

Better than ±2.0%(voltage change ±20%,resistance change:3kpa—6kpa)

Stability

(0~2000)Pa

1Pa

±1.0%FS

Dynamic pressure

(-30~30)kPa

0.01kPa

±1.0%FS

Static pressure

(-30~30)kPa

0.01kPa

±2.0%FS

Total pressure

(-40~0)kPa

0.01kPa

±1.0%FS

Flowrate pre-meter pressure

(-55~125)℃

0.1℃

±2.5℃

Flowrate pre-meter temperature

(0~800)℃

0.1℃

±3.0℃

Flue gas temperature

(1~45)m/s

0.1m/s

±4.0%

Atmospheric pressure

(60~130)kPa

0.1kPa

±0.5kPa

Auto tracking Precision

——

——

±3%

Max.sampling volume

9999.9L

0.1L

±2.5%

Isokinetic tracking

response time

≤10s

Load capacity of pump

≥50L/min(when resistance is 20 PA)

Size

(length 270×width 170×height 265)mm

Weight

About 5.8kg(battery include)

Noise

<65dB(A)

Power consumption

<180W

6.2 Flue gas technical index

Parameter

Range

Resolution

Error

Sampling flow

1.0L/min

0.1L/min

±5%

O2(optional)

(0~30)%

0.1%

error:Better than±5%

repeatability:≤2.0%

Response time:≤90s

Stability:indication change within 1h<5%

expected life:2 years in air (beside CO2)

SO2(optional)

(0~5700)mg/m3

1mg/m3

SO2

(Low concentration)

(0~570)mg/m3

1mg/m3

NO(optional)

(0~1300)mg/m3

1mg/m3

NO2(optional)

(0~200)mg/m3

1mg/m3

CO(optional)

(0~5000)mg/m3

1mg/m3

H2S(optional)

(0~300)mg/m3

1mg/m3

CO2(optional)

(0~20)%

0.01%

 