ZR-3061 Flue Gas Flow Rate Tester
product detail

1、 Host
2、 power adapter
3、 smoke temperature wire
4、 silicone rubber tube (bule & orange)
5、 Main aluminum box
6、 product manual
7、 ZR-D06B TMS probe & Accessory box
Features
1. Lightweight
> LCD display, English menu operation.
> Light, portable, and easy to operate.
2. High Test Efficiency
> Imported high-precision micro-differential pressure sensor: high precision, and small temperature drift.
> Calculate the average flow rate, average pressure, flue gas flow and other parameters automatically.
> Automatic zero correction and software calibration functions to ensure the measurement accuracy.
3. Long battery life
> Built-in lithium-ion rechargeable battery: can be used continuously for more than 24 hours.
> Can save 200 groups of measurement data without lost after shutdown.
Parameters
|
Parameters |
Range |
Resolution |
Maximum permitted error |
|
Flue gas dynamic pressure |
(0 ~ 2000) Pa |
1 Pa |
± 2% |
|
Flue gas static pressure |
(-30 ~ 30) kPa |
0.01 kPa |
± 4% |
|
Flue gas temperature |
(0 ~ 500) ℃ (expandable) |
1 ℃ |
±3 ℃ |
|
Flue gas flow rate |
(1 ~ 45) m/s |
- |
± 5% |
|
Ambient atmospheric pressure |
(50 ~ 130) kPa |
||
|
Operating temperature |
(-20 ~ 50) ° C |
||
|
Charging time |
< 6h |
||
|
Battery operating time |
> 24h |
||
|
Power adapter |
Input AC (100~240) V, 50/60Hz; Output DC5V 2A |
||
|
Size |
(length 85 x width 55 x height 140) mm |
||
|
Weight |
About 0.5kg |
||
|
Power consumption |
≤ 0.5 W |
||