Leave Your Message
THC Analyzer  FID ZR-3130

Environmental monitoring products

THC Analyzer FID ZR-3130

 THC Analyzer is a portable environmental analyzer  can detect almost all organic and inorganic compounds. Identify various pipeline and valve components, discharge ports and sealing systems quickly, helping users leakage detection and repair points. Flame ionization detector (FID) designed to perform inspections, HAZMAT, Emergency Response and many other types of total hydrocarbon(VOC) detection.

  • Model ZR-3130
  • Test Method FID (PID optional)
  • FID test range 1-50000ppm
  • Data read By mobile phone or print real-time data by bluetooth printer

Video

What is Leak Detection and Repair (LDAR)?

Leak Detection and Repair (LDAR) is the process by which oil and gas, chemical, and/or petrochemical equipment is monitored for the location and volume of unintended leaks. LDAR requires manufacturing organizations to account for volatile organic compounds (VOCs)  they emit into the atmosphere. These leaks must be reported on an annual or semiannual basis as required by multiple governments around the world to stem the harmful environmental impact of VOC emissions.

Standards

Governments globally are implementing LDAR regulations to combat the health and environmental impacts of liquid and gas leaks. The primary targets for these regulations are VOCs and HAPs (hazardous air pollutants) emitted from petroleum refineries and chemical manufacturing facilities.

US method 21

SOR/2020-231

EN 15446

Features

As a portable environmental analyzer, THC Analyzer has more than 1000 clients and many advantages:

  • • WIDE RANGE & FAST RESPONSE
    > FID sensor wide range: 1-50000ppm
    > Fast response time<3.5s
    > Dual FID/PID technology,O2 senor are also acceptable.
  • • EXTERNAL Bluetooth CONTROL
    > ZR-3130 includes powerful datalogging software that can be used to create electronic records of inspections.
    > Users can check data in Mobile phone from LDAR Software or print real-time data by bluetooth printer.



  • 1
  • THC Analyzer FID ZR-3130
STABILITY OF FID FLAMES
> Bypass design. When O2 is below 16%,
don’t worry about FID flames will flame down.
• CONTROL OF HYDROGEN
> Built in a solid hydrogen cylinder.
> Explosion protected and easy to replaceable
  • 2
  • THC Analyzer FID ZR-3130 (3)
  • • PORTABILITY & BATTERY
    > Built in explosion-proof battery with a long service life.
    > Portable, smaller, exquisite appearance. ZR-3130 is more friendly and easier for the users.


  • • EXPLOSION-PROOF QUALIFIED

    > ATEX certificate (Ex II 2 G Ex db ib IIC T4 Gb)

  • 3
  • RZ-3130

Deliver Goods

45

Gas leakage from refineries and chemical factory

6
Petroleum and petrochemical industry
7

A portable FID analyzer that measures VOCs in ambient air. This latest LDARtools to optimize your measurements in fugitive emissions in ATEX environments.

Parameters

Range

Accuracy

Linear

FID

1-50000ppm of methane

±10% of reading or ±1.0 ppm,

whichever is greater, from 1.0 to 10,000 ppm.

O2

0~30%

±5%

Repeatability

±2% at 500 ppm of methane

Detection limit

0.5 ppm of methane

Response time

Less than 3.5 seconds for 90% of final value, using 10000 ppm of methane

Flowrate

1.2L/min±10%

Battery

Operating time more than 10 hours at 0 °C.

Fully charged in less than 10 hours.

Hydrogen supply operating time

10 hours of continuous operation, starting from a cylinder charged

up to 15.3 MPa (2200 psi)

Data Storage

1 per second to 999 minutes

Data storage interval: every 15s

Host Size

H280 x L220 x T90 mm

Host Weight

FID only: about 3kg

Working Condition

(-10~+45)℃, (15 ~ 95)%RH

8