We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance for Mask Filtration Test , Kn95 Filtration Test Machine , N95 Filter Test Machine , "Making the Products of High Quality" is the eternal goal of our company. We make unremitting efforts to realize the goal of "We Will Always Keep in Pace with the Time".
Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray Detail:

US $35,000-70,000 / Piece

Introduction

ZR-1006 mask particulate filtration efficiency and air flow resistance tester is applicable to test the particle filtration efficiency and airflow resistance of masks and filter materials for centers of medical device inspection, security inspection center, drug inspection center, centers of diseases control and prevention, center of textile inspection, hospitals and mask R&D manufacturers.

Features

High definition LCD colored touch screen makes contents more intuitive and operation easier.

The equipped dedicated salt aerosol generators can generate aerosol in specific size and concentration.

Equipped multiple series of special fixtures are applicable to the test of various types of masks

Embedded long life photometer module, automatically count sampling time and prompt light path cleaning

To prevent human intervention, it can automatically calculate filtration efficiency and test airflow resistance of masks.

The embedded high-precision electronic flowmeter and high-performance sampling pump can insure the stability of flow. 

Embedded compressor has the function of automatic pneumatic clamping.

Equipped with electrostatic removal device

The automatic infrared anti-pinch protection function to protect personnel safety.

No aerosol leakage, strong operator protection

Data of detection can be exported by USB disk or printed by Bluetooth printer.

Optional oil or salt aerosol generator.

Standards

GB/T 32610-2016 Technical specification of daily protective mask

GB/2626-2019 Respiratory protection——Non-powered air-purifying particle respirator

GB 19082-2009 Technical requirements for single-use protective clothing for medical use

GB 19083-2010 Technical requirements for protective face mask for medical use

TAJ 1001-2015 PM2.5 Protective mask

T/CNTAC 55—2020 T/CNITA 09104——2020 Civil sanitary mask

T/CTCA 7—2019 Ordinary protective mask

YY 0469-2011 Surgical mask

EN 149 Respiratory protective devices – Filtering half masks to protect against particles – Requirements, testing, marking

NIOSH 42 CFR Part 84 Respiratory Protective Devices

Specifications

The Main Parameter Parameter Range Resolution Maximum Permissible Error

Median diameter of salt aerosol

(0.075) μm

/

±0.02

Median diameter of paraffin aerosol (Optional)

(0.185) μm

/

±0.02

Test flow

(8~100) L/min

0.1 L/min ±2.0%

Range of pressure detection

(0~2500) Pa 0.1 Pa ±2.0%

Range of concentration detection

(0.001-200) mg/m3 0.001 mg/m3  

Precision of test

/ / 1%FS

Repeatability of test

/ / 2%

Operation temperature

0~50℃

Instrument noise

<60 dB(A)

Power supply

AC 220 V±10%,50 Hz

Host size(L×W×H)

(Length 550 × Width 550 × Height 1630) mm

Power consumption

<300 W

Weight of host

About 90 kg

 

 

Deliver Goods

deliver goodsItaly
Product detail pictures:

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures


Related Product Guide:

We emphasize progress and introduce new merchandise into the market each and every year for Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray , The product will supply to all over the world, such as: Cyprus, Adelaide, Haiti, Our Company has professional engineers and technical staff to answer your questions about maintenance problems, some common failure. Our product quality assurance, price concessions, any questions about the products, Please feel free to contact us.
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
5 StarsBy Nelly from kazan - 2018.02.04 14:13
As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
5 StarsBy Jason from Estonia - 2017.08.28 16:02
Write your message here and send it to us