Using a total scientific good quality management process, superior high quality and excellent faith, we get great name and occupied this field for Disposable Mask Filter Test Device , Kn95 Test Equipment , Bfe , Special emphasis around the packaging of merchandise to avoid any damage during transportation,Detailed interest into the useful feedback and strategies of our esteemed shoppers.
Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray Detail:

US $35,000-70,000 / Piece

Introduction

ZR-1006 mask particulate filtration efficiency and air flow resistance tester is applicable to test the particle filtration efficiency and airflow resistance of masks and filter materials for centers of medical device inspection, security inspection center, drug inspection center, centers of diseases control and prevention, center of textile inspection, hospitals and mask R&D manufacturers.

Features

High definition LCD colored touch screen makes contents more intuitive and operation easier.

The equipped dedicated salt aerosol generators can generate aerosol in specific size and concentration.

Equipped multiple series of special fixtures are applicable to the test of various types of masks

Embedded long life photometer module, automatically count sampling time and prompt light path cleaning

To prevent human intervention, it can automatically calculate filtration efficiency and test airflow resistance of masks.

The embedded high-precision electronic flowmeter and high-performance sampling pump can insure the stability of flow. 

Embedded compressor has the function of automatic pneumatic clamping.

Equipped with electrostatic removal device

The automatic infrared anti-pinch protection function to protect personnel safety.

No aerosol leakage, strong operator protection

Data of detection can be exported by USB disk or printed by Bluetooth printer.

Optional oil or salt aerosol generator.

Standards

GB/T 32610-2016 Technical specification of daily protective mask

GB/2626-2019 Respiratory protection——Non-powered air-purifying particle respirator

GB 19082-2009 Technical requirements for single-use protective clothing for medical use

GB 19083-2010 Technical requirements for protective face mask for medical use

TAJ 1001-2015 PM2.5 Protective mask

T/CNTAC 55—2020 T/CNITA 09104——2020 Civil sanitary mask

T/CTCA 7—2019 Ordinary protective mask

YY 0469-2011 Surgical mask

EN 149 Respiratory protective devices – Filtering half masks to protect against particles – Requirements, testing, marking

NIOSH 42 CFR Part 84 Respiratory Protective Devices

Specifications

The Main Parameter Parameter Range Resolution Maximum Permissible Error

Median diameter of salt aerosol

(0.075) μm

/

±0.02

Median diameter of paraffin aerosol (Optional)

(0.185) μm

/

±0.02

Test flow

(8~100) L/min

0.1 L/min ±2.0%

Range of pressure detection

(0~2500) Pa 0.1 Pa ±2.0%

Range of concentration detection

(0.001-200) mg/m3 0.001 mg/m3  

Precision of test

/ / 1%FS

Repeatability of test

/ / 2%

Operation temperature

0~50℃

Instrument noise

<60 dB(A)

Power supply

AC 220 V±10%,50 Hz

Host size(L×W×H)

(Length 550 × Width 550 × Height 1630) mm

Power consumption

<300 W

Weight of host

About 90 kg

 

 

Deliver Goods

deliver goodsItaly
Product detail pictures:

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures

Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray detail pictures


Related Product Guide:

We have been proud from the higher consumer gratification and wide acceptance due to our persistent pursuit of high quality both on product or service and service for Short Lead Time for Filtration Efficiency Tester - ZR-1006 Mask Particulate Filtration Efficiency and Air flow Resistance Tester – Junray , The product will supply to all over the world, such as: New Zealand, Ecuador, South Africa, Further, we are supported by highly experienced and knowledgeable professionals, who have immense expertise in their respective domain. These professionals work in close coordination with each other to offer our clients an effective range of products.
This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
5 StarsBy Martin Tesch from Venezuela - 2018.06.19 10:42
In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
5 StarsBy Madeline from Melbourne - 2017.06.16 18:23
Write your message here and send it to us