Quality Inspection for Kn95 Air Resistance Test - ZR-1211 Mask breath resistance tester – Junray
Quality Inspection for Kn95 Air Resistance Test - ZR-1211 Mask breath resistance tester – Junray Detail:
US $9,000-20,000 / Piece
Introduction
ZR-1211 mask resistance tester is used to test inhalation and exhalation resistance of masks in regulated test condition. Compatible to multiple flow rates, is suitable to perform related inspection and test of masks for mask manufacturers, national inspection institutes of labor protection devices.
Standards
GB 2626-2019 Respiratory protective equipment Non-powered air-purifying particle respirator
GB/T 38880-2020 Technical specification of children mask
GB/T 32610-2016
EN 149:2001-10 Respiratory protective devices – Filtering half masks to protect against particles – Requirements, testing, marking
ASTM F2100-2111 Standard Specification for Performance of Materials Used in Medical Face Masks
Features
Standard head form conforms to requirements in annex B of GB 2626-2019, optional multiple types of head forms.
7-inch high definition touch screen.
Electric flow meter,high precision flow control.
Automatic constant flow control, compatible to 30,40,45,85,90,95,160 L/min multiple flow rate.
Separately test inhalation and exhalation resistance.
Large-capacity data storage, real time save test data.
Support export to USB flash dish or print real-time of historical data with thermal printer.
Automatically judge whether the sample is qualified.
Automatic failure protection.
Specification
| Main parameter | Parameter range | Resolution | Maximum permitted error |
|
Test flow
|
160L/min | 0.1L/min | ±1L/min |
| 95L/min | 0.1L/min | ±1L/min | |
| 90L/min | 0.1L/min | ±1L/min | |
| 85L/min | 0.1L/min | ±1L/min | |
| 45 L/min | 0.1L/min | ±1L/min | |
| 30 L/min | 0.1L/min | ±1L/min | |
|
Pressure range |
±2000Pa | 1Pa | ±2Pa |
|
Data storage |
1000000 groups | ||
|
Dimension(W×D×H) |
(400×300×250)mm | ||
|
Overall weight |
About 8.8kg | ||
|
Overall power |
<250W | ||
Deliver Goods


Product detail pictures:
Related Product Guide:
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Quality Inspection for Kn95 Air Resistance Test - ZR-1211 Mask breath resistance tester – Junray , The product will supply to all over the world, such as: Austria, Iran, Latvia, We follow up the career and aspiration of our elder generation, and we're eager to open up a new prospect in this field, We insist on "Integrity, Profession, Win-win Cooperation", because we have now a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
By Chris Fountas from Berlin - 2017.06.16 18:23
We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
By tobin from Lithuania - 2018.09.12 17:18