Professional China Biosafety Cabinet Leakage Tester - ZR-6010 Aerosol photometer – Junray Detail:
US $10,000-35,000 / Piece
Introduction
ZR-6010 Aerosol photometer is designed base on Mie scatter principle, which is used to test whether there is leakage on HEPA filter. The instrument conforms to related national and industry standard, could realize rapid detection of upstream and downstream concentration detection and real-time display leakage on the host and handheld device, and could find leaking position rapidly and accurately. It is applicable to leakage detection of clean room, VLF bench, biosafety cabinet, glove box, HEPA vacuum cleaner, HVAC system, HEPA filter, negative pressure filtering system, operating theatre, nuclear filter system, collection protect filter.
Standards
GMP Factory and device
ISO14644-3:2005 Cleanrooms and associated controlled environments—Part 3:Test methods
GB 50591-2010 Code for construction and acceptance of cleanroom
YY0569-2005 Biosafety cabinet
NSF49-2002 Biosafety cabinet
Features
Long life laser light source;
Detected by high precision photomultiplier;
Support PAO and DOP multiple aerosol type;
Pixel and matrix colored display;
Equipped special handheld device, realize control, display and sampling function;
Large capacity data storage, real-time save sampling data;
Automatic light and voice alarm after exceeding set value;
Support export historical data to USB flash disk or print with thermal printer;
Real-time print detection data like leakage and so on;
Sampling data could be imported to PC via special software;
Automatic failure detection and protection.
Specification
| The Main Parameters | Parameter Range | Maximum Permitted Error(MPE) |
| Sampling flow | 28.3L/min | ±5% |
| Concentration detection rage | (0.0001~125)μg/L | |
| Leakage detection | 0.0001%~100% | |
| Detection precision | 0.01%~100% resolution is 1% | |
| Detection repeatability | 0.01%~100% resolution is 0.5% | |
| Data storage capacity | 1000 groups | |
| Power adapter | Input AC100~240V 50/60Hz Out put DC24V 6.67A | |
| Host size | (Length 380×width 400×height 170)mm | |
| Overall weight | About 8kg | |
| Overall power consumption | <100W | |
Conditions for running and storage:
| The Main Parameter | Parameter range |
| Environment temperature | (10~35)℃ |
| Environment humidity | 5%-85%(No condensation、No icing) |
| Storage requirements | (-10-40)℃ No condensation when relative humidity lower than 85%. |
Deliver Goods


Product detail pictures:
Related Product Guide:
With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future alongside one another with your esteemed enterprise for Professional China Biosafety Cabinet Leakage Tester - ZR-6010 Aerosol photometer – Junray , The product will supply to all over the world, such as: Jeddah, Amman, Roman, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.