Adhering into the principle of "quality, provider, performance and growth", we now have gained trusts and praises from domestic and intercontinental consumer for Mask Filter Tester , Mase Bfe , Mask Breath Test Device , Since the factory founded, we have committed to the development of new products. With the social and economic pace, we will continue to carry forward the spirit of "high quality, efficiency, innovation, integrity", and stick to the operating principle of "credit first, customer first, quality excellent". We will create a brilliant future in hair production with our partners.
Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray Detail:

Introduction

The ZR-1002 mask particle protection effect tester is to test the particle protection effect of masks by installing the national standard head from in the 500L self-cleaning test cabinet, then wear the mask on the head from, and import the mass median diameter  (0.6 ± 0.050) μm, concentration is 20mg / m³ of NaCl aerosol or mass median diameter (0.3 ± 0.050) μm, concentration is 20mg /m³ of oily aerosol into the self-cleaning test chamber, and the head form simulate breathing in sinusoidal curve, using upstream and downstream photometers to detect the concentration of salt aerosol and oil aerosol before and after the mask to evaluate the particle protective effect of the mask. The mask to be tested also can be worn on the national standard head form to automatically test the breathing resistance. It is suitable for the test of the particle protective effect of masks and filter materials by medical device inspection centers, disease prevention and control centers, hospitals, HEPA filter manufacturers, mask R&D manufacturers.

Standards

GB/T 32610-2016

GB2626-2019

GB/T 6165-2008

GB/T 38880-2020

Features

The integrated design of the particle protective effect test and breath resistance test, one machine for multiple purposes.

Self-cleaning test cabinet is equipped with operating gloves to facilitate the replacement of masks to be tested.

Three types of head form compatibility design, plug and play, easy to replace.

The external salt and oil aerosol generator can be controlled to adjust the concentration of particulate matter.

Large touch display design, automatically display curve of breath flow and automatic calculation of particle protection effect.

The anti-leakage design of the whole particulate matter to protect the safety of laboratory personnel.

Photometer has a long-life laser light source, detect with high-precision photomultiplier tube.

Count photometer working time, automatically prompt cleaning time.

The usage time of the HEPA filter is automatically counted, prompting to replace the HEPA filter.

Historical data can be exported via USB flash disk or printed via embedded printer.

Specifications

The main parameters

Parameter range Resolution

MPE (Maximum Permissible Error)

Sampling flow rate for concentration detection

1L/min 0.01L/min ±2.5%
Concentration detection range  (0.001~100)μg/L
Detection accuracy 1%
Mass median diameter of salt aerosol (0.6±0.05)μm
Mass median diameter of oil aerosol (0.3±0.05)μm
Simulated breathing curve Sine curve
Respiratory rate 20 times / min
Respiratory tidal volume 1.5L
Volume of self-cleaning cabinet 500L
Self-cleaning time  (1~5)min
Breath resistance test flow 85L/min 0.1L/min ±2.5%
Breat resistance test range (0~1500)Pa 1Pa ±1%
Power supply AC220V  50/60Hz
Host size (Length 1900 × Width 800 × Height 1840) mm
Host power consumption <300W
Host weight About 200kg

 

Deliver Goods

deliver goodsItaly
Product detail pictures:

Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray detail pictures

Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray detail pictures

Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray detail pictures

Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray detail pictures

Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray detail pictures


Related Product Guide:

With this motto in mind, we've turn into one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for Ordinary Discount Non-Woven Testing Equipment - ZR-1002 mask particle protection effect tester – Junray , The product will supply to all over the world, such as: Indonesia, Ukraine, Cyprus, With the support of our highly experienced professionals, we manufacture and supply best quality products. These are quality tested at various occasions to ensure only flawless range is delivered to customers, we also customize the array as per the need of customers to meet the requirement of customers.
The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
5 StarsBy Catherine from Riyadh - 2017.11.29 11:09
We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
5 StarsBy Dee Lopez from Angola - 2017.11.01 17:04
Write your message here and send it to us