Airborne Particle Counter (0.1μm) 1650
Contra particula ZR-1650 alta praecisio est 0.1μm particula calculi innixa laseris solidi status. Sampling rate of 28.3L/min (1CFM) habet et principio lucis spargens ad mensurandum quantitatem et quantitatem particularum suspensarum in aere, vndique ab 0.1, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7; 1.0, ad 5.0μm. Instrumentum portatile praecisionem est ut particulam assequendi computando usque ad 9 canales, automatice varias notitias mutant. Filtrum aedificato in HEPA ad aerem exauctum eliquandum instructum est. Instrumentum programmatum est consuetudo evoluta ad deprehensionem mundissimam, ad varias probationes necessarias ministrans.
Features
>Usque ad canales 9 experimenti, cumulus numeratio, partitio numeratio, modus retrahitur, modus numeri;
>7-inch touch color screen, friendly human-computer interaction.
>Diversa signa cleanroom signa, automatice an idoneus iudicare potest.
>Test report output, support UCL calculation.
>Tres-gradu usorum procuratio et audit typum ut notitia integritatis curet.
>Recipes preset assignari possunt cubiculis in diversis locis.
>Inaedificata summus praecisione fan, fluxus stabilis control
>Inaedificata HEPA filter ut filter exhauriunt
>Automatic nulla computatio sine linamentis in externis HEPA sparguntur.
> Support educendi notitias ad USB mico coegi et excudendi data per constructum-in printer; instructus dives communicationis interface.
>Ambiens temperatus, humiditas et pressura atmosphaerica parametri in testi notari possunt.
GMPBonum faciens praxim medicinae products
ISO 14644Cleanrooms et adiuncti imperium ambitibus
ISO 21501Lucem spargens aerium particula contra pro spatiis mundis
JJF 1190-2008Calibration specificatio pro calculis aerium particulae
JIS B 9921:2010Lucem spargens aerium particula contra pro spatiis mundis
GB/T 16292-2010Test methodus particularum aerium in camera munda (zona) industriae pharmaceuticae
GB/T 6167-2007Modi tentandi faciendi aerium particula contra
Parameter | Range |
Influunt Rate | 28.3L/min±2% |
Screen | VII-inch color tactus screen |
Magnitudo particula | 0.1、0.15、0.2、0.25、0.3、0.5、0.7、1.0、5.0μm |
Counting Efficiency | 0.1μm:50%±20%;>0.15μm:100%±10% |
Error particulae Location | 0.5μm、5μm ≤±30% |
Concentratio Error | 0.5µm≤±30%FS |
Repeatability | ≤10% FS in eadem test conditione |
Laser Source | Laser solidum-status |
Nulla comes | |
Sample Modus | Manuale, latae sententiae; cumulus numeratio, partitio numeratio; Modus defectus, numerus modus; UCL calculation |
Alarm | Sonus et terror visualis, vis humilis, alius casus abnormes eveniunt. |
Data Storage | 8GB,circiter (C) coetibus |
Area / locus / locus / consequat | Area, locus, locus, felis libere componi possunt |
Sampling mora | 0~1000min |
Sampling Tempus | 1s~1000min |
Sampling Volume | 0.47L~28300L |
Sampling Frequency | 1~1000 |
Sampling Intervallum | 1~1000min |
Operatio Operatio | (10~40)°C /,(20~95) %RH nulla condensatio |
Repono Environment | -20~50)℃, ≤85% RH |
Date | latae sententiae; USB export; aedificare in printer |
Potestas Supple | AC (100 ~ 240) V, (50~ 60) Hz |
Pugna | continua sampling ≥4 h |
sonitus | 60dB(A) |