Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray

Short Description:


Product Detail

Related Video

Feedback (2)

We have now sophisticated machines. Our solutions are exported to the USA, the UK and so on, enjoying a great reputation amid consumers for Medical Mask Filtering Efficiency Tester , Disposable Mask Viral Test Machine , Bfe , We, with open arms, invite all interested buyers to visit our website or contact us directly for further information.
Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray Detail:

priceUS $48,000-90,000/ Piece

Introduction

The main specifications of the ZR-1000A mask virus filtration efficiency (VFE) tester conform to the YY/T1497-2016 < Evaluation test method for the viral filtration efficiency(VFE) of medical protective face mask materials–Test method using Phi-X174 bacteriophage>, The method of double gas path simultaneous comparison sampling improves the accuracy of sampling. It is applicable to the performance test of viral filtration efficiency by the metrological verification department, scientific research institutes, mask manufacturers and other relevant departments.

Features

Negative pressure test system ensures the safety of operators;

The negative pressure cabinet is equipped with peristaltic pump, A and B two-path six stage Anderson sampler;

The flow of peristaltic pump can be set;

The nebulization volume of the special microbial aerosol generator can be set and the nebulization performance is good;

Controlled by embedded high-speed industrial microcomputer;

10.4-inch industrial high brightness colored touch screen;

USB port, supporting data transfer to USB flash disk;

Build-in high brightness lights in the cabinet;

Build-in UV lamb for disinfection and sterilization;

Built in leakage protection switch to protect the safety of operators;

The inner layer of the cabinet is made of stainless steel by overall processing and forming, the outer layer is cold-rolled sheet sprayed by plastic;

Heat preservation and flame retardant is set between inner and outer layers;The front The front openable glass door is convenient for the experimental operator to observe and operate;

Detachable bracket with adjustable height;

The caster can be used for supporting and moving.
Specifications

Main Parameter Parameter Range Resolution MPE (Maximum Permissible Error)
Sampling flow of channel A (5-35) L/min 0.1L/min ±2.5%
Sampling flow of channel B (5-35) L/min 0.1L/min ±2.5%
Nebulization flow rate (6-8) L/min 0.1L/min ±5.0%
Peristaltic pump flow (0.006-3.0) mL/min 0.001ml/min ±2.5%
Front pressure of A-path flowmeter (-50~0) kPa 0.01kPa ±2.5%
Front pressure of B-path flowmeter (-50-0) kPa 0.01kPa ±2.5%
Front pressure of spray flowmeter (0-300) kPa 0.1kPa ±2.5%
Negative pressure in aerosol chamber (-90~120) Pa 0.1Pa ±2.0%
working temperature (0-50) ºC
Cabinet negative pressure (-50~200) Pa
Data storage capacity >100000 group
Characteristics of HEPA filter Filter efficiency for particles above 0.3μm ≥99.99%
Mean mass diameter of aerosol generator Average particle diameter (3.0 ±0.3) μm, geometric standard deviation ≤ 1.5
Size of aerosol chamber (length 600×diameter 85×thickness 3) mm
Ventilation flow OF negative pressure cabinet ≥5m3/min
Dimensions of negative pressure cabinet door (length 1000×width 730)mm
Host size (length 1180×width 650×height 1300)mm
Bracket size (length 1180×width 650×height 600)mm, height adjustable within 100mm
Working power supply AC220V±10%,50Hz
Instrument noise <65dB(A)
Weight of whole machine About 250kg
Overall power consumption <1500W

Deliver Goods

deliver goodsItaly
Product detail pictures:

Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray detail pictures

Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray detail pictures

Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray detail pictures

Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray detail pictures

Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray detail pictures


Related Product Guide:

carry on to further improve, to guarantee merchandise high-quality in line with market and buyer standard necessities. Our organization has a top quality assurance procedure have already been established for Hot sale Mask Perticulate Filtration Efficiency Testing Instrument - Mask Viral Filtration Efficiency (VFE) Detector – Junray , The product will supply to all over the world, such as: Latvia, Philippines, Somalia, We will do our utmost to cooperate & satisfied with you relying on top-grade quality and competitive price and best after service ,sincerely look forward to cooperating with you and make achievements in the future!
The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
5 StarsBy Dinah from Los Angeles - 2017.09.29 11:19
Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
5 StarsBy Barbara from Afghanistan - 2017.02.18 15:54
Write your message here and send it to us