Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray

Short Description:


Product Detail

Related Video

Feedback (2)

With advanced technologies and facilities, strict high-quality handle, reasonable rate, superior services and close co-operation with prospects, we are devoted to furnishing the best price for our customers for N95 Air Resistance Tester , Mask Testing Instrument , Mask Filtration Test Machine , We think this sets us apart from the competition and makes prospects choose and trust us. We all wish to build win-win deals with our customers, so give us a call today and make a new friend!
Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray Detail:

Introduction

The ZR-1002 mask particle protection effect tester is to test the particle protection effect of masks by installing the national standard head from in the 500L self-cleaning test cabinet, then wear the mask on the head from, and import the mass median diameter  (0.6 ± 0.050) μm, concentration is 20mg / m³ of NaCl aerosol or mass median diameter (0.3 ± 0.050) μm, concentration is 20mg /m³ of oily aerosol into the self-cleaning test chamber, and the head form simulate breathing in sinusoidal curve, using upstream and downstream photometers to detect the concentration of salt aerosol and oil aerosol before and after the mask to evaluate the particle protective effect of the mask. The mask to be tested also can be worn on the national standard head form to automatically test the breathing resistance. It is suitable for the test of the particle protective effect of masks and filter materials by medical device inspection centers, disease prevention and control centers, hospitals, HEPA filter manufacturers, mask R&D manufacturers.

Standards

GB/T 32610-2016

GB2626-2019

GB/T 6165-2008

GB/T 38880-2020

Features

The integrated design of the particle protective effect test and breath resistance test, one machine for multiple purposes.

Self-cleaning test cabinet is equipped with operating gloves to facilitate the replacement of masks to be tested.

Three types of head form compatibility design, plug and play, easy to replace.

The external salt and oil aerosol generator can be controlled to adjust the concentration of particulate matter.

Large touch display design, automatically display curve of breath flow and automatic calculation of particle protection effect.

The anti-leakage design of the whole particulate matter to protect the safety of laboratory personnel.

Photometer has a long-life laser light source, detect with high-precision photomultiplier tube.

Count photometer working time, automatically prompt cleaning time.

The usage time of the HEPA filter is automatically counted, prompting to replace the HEPA filter.

Historical data can be exported via USB flash disk or printed via embedded printer.

Specifications

The main parameters

Parameter range Resolution

MPE (Maximum Permissible Error)

Sampling flow rate for concentration detection

1L/min 0.01L/min ±2.5%
Concentration detection range  (0.001~100)μg/L
Detection accuracy 1%
Mass median diameter of salt aerosol (0.6±0.05)μm
Mass median diameter of oil aerosol (0.3±0.05)μm
Simulated breathing curve Sine curve
Respiratory rate 20 times / min
Respiratory tidal volume 1.5L
Volume of self-cleaning cabinet 500L
Self-cleaning time  (1~5)min
Breath resistance test flow 85L/min 0.1L/min ±2.5%
Breat resistance test range (0~1500)Pa 1Pa ±1%
Power supply AC220V  50/60Hz
Host size (Length 1900 × Width 800 × Height 1840) mm
Host power consumption <300W
Host weight About 200kg

 

Deliver Goods

deliver goodsItaly
Product detail pictures:

Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray detail pictures

Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray detail pictures

Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray detail pictures

Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray detail pictures

Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray detail pictures


Related Product Guide:

Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction for Factory directly Bfe Kn95 - ZR-1002 mask particle protection effect tester – Junray , The product will supply to all over the world, such as: kazan, Rio de Janeiro, Luxembourg, We always insist on the management tenet of "Quality is first, Technology is basis, Honesty and Innovation".We are able to develop new products continuously to a higher level to satisfy different needs of customers.
In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
5 StarsBy Rae from Malta - 2018.09.21 11:44
This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
5 StarsBy Lulu from Argentina - 2017.11.12 12:31
Write your message here and send it to us