"Quality very first, Honesty as base, Sincere assistance and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for Mask Protection Performance Test , Viral Filtration Efficiency Test , Mask Inhalation Resistance Test , We welcome you to inquire us by call or mail and hope to build a successful and cooperative relationship.
2020 High quality Mask Bacterial Filtration Efficiency - ZR-1000 Mask Bacterial Filtration Efficiency (BFE) Tester – Junray Detail:

Introduction

Key specifications of Model ZR-1000 mask bacteria filtration efficiency tester (BFE) not only meet the requirements of B.1.1 in YY0469-2011 <technical requirements for medical surgical masks>, but also meet the requirements of ASTMF2100, ASTMF2101 and European EN14683 standards. What’s more, we made innovative improvements based on this, with double gas contrast sampling method at the same time, improve the precision of sampling. It is applicable to the performance test of the mask bacterial filtration efficiency by the metrological verification department, scientific research institutes, mask manufacturers and other relevant departments.

Features

The negative pressure test system ensures the safety of operators;

The negative pressure cabinet is equipped with peristaltic pump, A and B two-path six stage Anderson sampler;

The flow of peristaltic pump can be set;

The flow rate of microbial aerosol generator can be set.

Good nebulization performance;

Controlled by embedded high-speed industrial microcomputer;

10.4-inch industrial high brightness colored touch screen;

USB port, supporting data transfer of USB flash disk;

Built-in high brightness lights;

Built in leakage protection switch to protect the safety of operators;

The inner layer of the cabinet is made of stainless steel, and the outer layer is cold-rolled sheet sprayed by plastic;

Heat preservation and flame retardant is set between inner and outer layers;

The front openable glass door is convenient for the experimental operator to observe and operate;

Detachable bracket with adjustable height;

The caster can be used for supporting and moving.

Standards

EN14683-2019

ASTM F2100, STM F2101

YY 0469-2011

YY/T 0969-2013

GB/T 38880-2020

T/CNTAC 55—2020 T/CNITA 09104——2020

T/CTCA 7—2019

Specifications

Main parameters

 Parameter range

Resolution

MPE (Maximum Permissible Error)

Sampling Flow Rate of A 28.3L/min 0.1L/min ±2.5%
Sampling Flow Rate of B 28.3L/min 0.1L/min ±2.5%
Nebulization flow rate (8~10)L/min 0.1L/min ±5.0%
Peristaltic pump flow

(0.006~3.0) mL/min

0.001mL/min ±2.5%
Front pressure of A-path flowmeter (-20~0)kPa 0.1kPa ±2.5%
Front pressure of B-path flowmeter (-20~0)kPa 0.1kPa ±2.5%
Front pressure of nebulizer (0~300)kPa 0.1kPa ±2.5%
Negative pressure in aerosol chamber (-90~-120)Pa 1Pa ±2.0%
Operation temperature (0~50)℃
Cabinet negative pressure (-50~-200)Pa
Data storage capability >100000 groups
Characteristics of HEPS filter Filtration efficiency for particles is above 0.3μm ≥ 99.99%
Mean mass diameter of aerosols Average particle diameter is (3.0 ± 0.3) μm, geometric standard deviation ≤ 1.5
Captured particle size of Two-path 6-stage Anderson sampler 1st stage > 7 μm, 2nd stage (4.7-7) μm,3rd stage (3.3-4.7) μm, 4th stage(2.1-3.3) μm, 5th stage (1.1-2.1) μm, 6th stage (0.6-1.1) μm
Size of aerosol chamber (length 600× diameter 85× thickness 3) mm
Total number of positive quality control sampler (2200±500) CFU
Ventilation flow rate of negative pressure cabinet ≥5m3/min
Dimensions of negative pressure cabinet door (length 1000× width 730) mm
Host size (length 1180× width 650× height 1300) mm
Bracket size (length 1180× width 650× height 600) mm, height adjustable within 100mm
Power supply AC220V±10%,50Hz
Instrument noise <65dB(A)
Weight of whole machine About 250 kg
Overall power consumption <1500W

Deliver Goods

deliver goodsItaly
Product detail pictures:

2020 High quality Mask Bacterial Filtration Efficiency - ZR-1000 Mask Bacterial Filtration Efficiency (BFE) Tester – Junray detail pictures

2020 High quality Mask Bacterial Filtration Efficiency - ZR-1000 Mask Bacterial Filtration Efficiency (BFE) Tester – Junray detail pictures

2020 High quality Mask Bacterial Filtration Efficiency - ZR-1000 Mask Bacterial Filtration Efficiency (BFE) Tester – Junray detail pictures


Related Product Guide:

Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for 2020 High quality Mask Bacterial Filtration Efficiency - ZR-1000 Mask Bacterial Filtration Efficiency (BFE) Tester – Junray , The product will supply to all over the world, such as: Denmark, panama, Chile, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.
On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
5 StarsBy Octavia from Riyadh - 2017.06.29 18:55
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
5 StarsBy Gladys from Netherlands - 2017.06.22 12:49
Write your message here and send it to us