Introduction

Key specifications of Model ZR-1000 mask bacteria filtration efficiency tester (BFE) not only meet the requirements of B.1.1 in YY0469-2011 <technical requirements for medical surgical masks>, but also meet the requirements of ASTMF2100, ASTMF2101 and European EN14683 standards. What’s more, we made innovative improvements based on this, with double gas contrast sampling method at the same time, improve the precision of sampling. It is applicable to the performance test of the mask bacterial filtration efficiency by the metrological verification department, scientific research institutes, mask manufacturers and other relevant departments.

Features

The negative pressure test system ensures the safety of operators;

The negative pressure cabinet is equipped with peristaltic pump, A and B two-path six stage Anderson sampler;

The flow of peristaltic pump can be set;

The flow rate of special microbial aerosol generator can be set.

Good nebulization performance, aerosol size conforms to global standards;

Controlled by embedded high-speed industrial microcomputer;

10.4-inch industrial high brightness colored touch screen;

USB port, supporting data transfer to USB flash disk;

Support Bluetooth printing;

Built-in high brightness lights;

Built in leakage protection switch to protect the safety of operators;

The inner layer of the cabinet is made of stainless steel, and the outer layer is cold-rolled sheet sprayed by plastic;

Heat preservation and flame retardant is set between inner and outer layers;

The front openable glass door is convenient for the experimental operator to observe and operate;

Detachable holder, and the caster can be used for supporting and moving.

Retractable rotating display screen, convenient to operate;

The negative pressure cabinet has a built-in operating key board, which is corrosion-resistant and UV-resistant, make it convenient for operations.

Standards

EN14683-2019

ASTM F2100, STM F2101

YY 0469-2011

YY/T 0969-2013

GB/T 38880-2020

T/CNTAC 55—2020 T/CNITA 09104——2020

T/CTCA 7—2019

Specifications

Main parameters Parameter range  Resolution

MPE (Maximum Permissible Error)

Sample Flow Rate of A 28.3L/min 0.1L/min ±2.5%
Sample Flow Rate of B 28.3L/min 0.1L/min ±2.5%
Nebulization flow rate (6~10)L/min 0.1L/min ±5.0%
Peristaltic pump flow

(0.006~3.0) mL/min

0.01mL/min ±2.5%
Front pressure of A-path flowmeter (-20~0)kPa 0.1kPa ±2.5%
Front pressure of B-path flowmeter (-20~0)kPa 0.01kPa ±2.5%
Front pressure of nebulizer (0~50)kPa 0.01kPa ±2.5%
Negative pressure in aerosol chamber (-90~-120)Pa 0.1Pa ±2.0%
Operation temperature (0~50)℃
Cabinet negative pressure (-50~-200)Pa
Data storage capability >100000 groups
Characteristics of HEPA filter Filter efficiency for particles is above 0.3μm ≥ 99.99%
Mean mass diameter of aerosol Average particle diameter is (3.0 ± 0.3)μm, geometric standard deviation ≤ 1.5
Captured particle size of Two-path 6-stage Anderson sampler 1st stage > 7 μm, 2nd stage (4.7-7) μm,3rd stage (3.3-4.7) μm, 4th stage(2.1-3.3) μm, 5th stage (1.1-2.1) μm, 6th stage (0.6-1.1) μm
Size of aerosol chamber (length 600× diameter 85× thickness 3) mm
Total number of positive quality control sampler (2200±500) CFU/mL
Ventilation flow rate of negative pressure cabinet ≥5m3/min
Dimensions of negative pressure cabinet door (length 1100× width 780) mm
Host size (length 1050× width 635× height 1310) mm
Bracket size (length 1050× width 635× height 650) mm
Power supply AC220V±10%,50Hz
Instrument noise <65dB(A)
Weight of whole machine About 180 kg
Overall power consumption <500W

 

Deliver Goods

deliver goodsItaly
Product detail pictures:

2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray detail pictures

2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray detail pictures

2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray detail pictures

2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray detail pictures

2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray detail pictures


Related Product Guide:

We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for 2020 China New Design Kn95 Protection Effect Tester - Mask Bacterial Filtration Efficiency (BFE) tester – Junray , The product will supply to all over the world, such as: Mozambique, Curacao, Portland, We welcome an opportunity to do business with you and hope to have pleasure in attaching further details of our products. Excellent quality, competitive price, punctual delivery and dependable service can be guaranteed. For further inquires please do not hesitate to contact us.
After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
5 StarsBy Betty from India - 2017.03.07 13:42
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
5 StarsBy Tina from Madrid - 2017.05.02 11:33
Write your message here and send it to us